Cheat Sheet

AV Blocks, Bundle Branch Blocks and Pre-excitation

Criteria tables for every degree of AV block, AV dissociation, bundle branch and fascicular blocks, and WPW, with what to measure and when to report

Reviewed by Alex G, BSN, RN, CEN, CCRN, CMC, NREMT-P · Checked against current sources November 2026

Practice 86 AV Blocks, Bundle Branch Blocks and Pre-excitation questions free

Page 1 of the AV Blocks, Bundle Branch Blocks and Pre-excitation PDF, a printed page in columns with sections on Measure before you name, AV blocks, Block or dissociation?, Bundle branch and fascicular blocks, Pre-excitation and Example stripsEnlarge

One-page PDFLetter landscape, ready to print or keep with your notes

View PDFDownload

AV Blocks, Bundle Branch Blocks and Pre-excitation: one-page PDF preview

Page 1 of the AV Blocks, Bundle Branch Blocks and Pre-excitation PDF, a printed page in columns with sections on Measure before you name, AV blocks, Block or dissociation?, Bundle branch and fascicular blocks, Pre-excitation and Example strips

View PDFDownload

Measure before you name

AV blocks

BlockWhat you measureUsual levelReport
First-degreePR over 0.20 s, constant; every P conductsAV nodeDocument the PR
Mobitz I (Wenckebach)PR lengthens until a P does not conduct; shortest PR after the pauseAV node if the QRS is narrowPer protocol
Mobitz IIPR the same before and after the dropped P; pause equals two R-RHis bundle or bundle branches; QRS often widePromptly
2:1Every second P blocked; regular P-P; constant PR on conducted beatsEitherAs '2:1 AV block'
High-gradeTwo or more P waves in a row blocked (3:1, 4:1); conducted beats keep one PRUsually below the nodeAt once
Third-degreeNo P conducts; PR varies at random; atria faster than the escapeNarrow escape higher, wide escape lowerAt once; check the patient
Lead II · 25 mm/s
2:1 AV block: regular P waves (here 84/min), every second one not conducted, the same PR on each conducted beat, ventricular rate half the atrial (42).

Block or dissociation?

FindingThird-degree blockAV dissociation without block
RatesAtria faster than the ventriclesVentricles as fast as or faster than the atria; isorhythmic if nearly equal
CauseAtrial impulses cannot get throughSinus slows below the junction, or a junctional or ventricular focus speeds up (AIVR, VT)
Conducted beatsNoneA well-timed P can capture: an early beat with a normal QRS

Dissociation with occasional conducted beats at a constant PR is high-grade block, not third-degree. A pause with no P wave in it is not AV block at all: it is a sinus pause or SA block.

Bundle branch and fascicular blocks

PatternQRSKey leadsAxis
RBBB0.12 s or morerSR′ ('M') in V1–V3; wide, slurred S in I, aVL, V5–V6Usually normal
LBBB0.12 s or moreDominant S (rS or QS) in V1; broad, notched R with no q in I, aVL, V5–V6Usually −30° to +60°
Incomplete RBBB or LBBBUnder 0.12 sSame shapesAs above
LAFBUnder 0.12 sqR in I and aVL; rS in II, III, aVFLeft, −45° to −90°
LPFBUnder 0.12 srS in I and aVL; qR in II, III, aVFRight, beyond +90°, other causes excluded
Nonspecific IVCDWideNeither RBBB nor LBBB shapeAny

Pre-excitation

PatternECG
WPW patternPR under 0.12 s; delta wave (slurred QRS upstroke); QRS often wide; ST-T opposite the QRS. Syndrome = pattern plus tachycardia
Short PR, no delta wavePR under 0.12 s, normal QRS (the disputed 'LGL' label)
Concealed pathwayNormal resting ECG; the pathway conducts only backward
Orthodromic AVRTRegular, narrow, 120–250/min; no delta wave; inverted P after the QRS in II, III, aVF
Antidromic AVRTRegular and wide, fully pre-excited; can look exactly like VT
Pre-excited AFIrregularly irregular, very fast, wide; QRS shape changes beat to beat
Lead II · 25 mm/s
Pre-excited AF: irregular, very fast (mean here about 220/min), wide complexes that change from beat to beat. A shortest pre-excited R-R of 250 ms (6¼ small boxes) or less marks a high-risk pathway.

Example strips

Lead II · 25 mm/s
WPW pattern (here 75/min): a short PR (about 0.10 s) running straight into a slurred delta wave, and a QRS widened to about 0.12 s.
Practice AV Blocks, Bundle Branch Blocks and Pre-excitation questions free in your browser86 exam-style questions with rationales. No account or download needed.

In depth

The one-page summary above is what the PDF prints. These sections go further.

Measuring the PR and the pauses

AV block is diagnosed from the relationship between P waves and QRS complexes, so the P waves are measured first and on their own. Set the calipers on two consecutive P waves and walk them across the strip, through the pauses and through the T waves, where a P wave can hide. Then measure the PR on every conducted beat. The full method for measuring intervals is on the Paper, Settings and Measurement page.

The PR is rate-dependent. The Brazilian ECG guideline defines first-degree block as a PR over 200 ms at a heart rate of 50 to 90/min, and its exercise guideline notes that the PR normally shortens as the rate rises, to about 100 ms in healthy people at high exercise rates. A PR that is merely long at rest often shortens with exercise. A PR over 0.3 s may cause exercise intolerance (Merck); the exercise guideline gives the reason: the PR fails to shorten as the rate rises, so atrial contraction falls too close to the previous ventricular contraction. First-degree block is found in up to 7.8% of healthy people, and its usual site is the AV node (da Silva 2021).

Pauses sort themselves by what lies inside them. A pause that holds an on-time P wave with no QRS is AV block. A pause with an early, differently shaped P wave on the preceding T wave is a blocked PAC. A pause with no P wave at all is sinus arrest or SA exit block: LITFL notes that SA block shows the same patterns as AV block, but can be judged only from the P waves, because sinus node firing itself leaves no mark on the ECG.

Second-degree block: Mobitz I, Mobitz II and 2:1

In Mobitz I (Wenckebach) the PR lengthens with each beat until a P wave is not conducted. The PR is longest just before the dropped beat and shortest just after it. The biggest increase usually comes between the first and second beats, so the increments shrink and the R-R intervals shorten as the cycle goes on, while the P-P stays about constant (LITFL). The pause is less than twice the duration of any other R-R interval (Merck). Cycles are named by P waves to QRS complexes, such as 3:2, 4:3 or 5:4. Mobitz I with a narrow QRS is nearly always in the AV node; with a QRS of 0.12 s or more it is in the His-Purkinje system in 60–70% of patients (Merck, da Silva 2021). Mobitz I occurs in 1–2% of healthy young people, especially during sleep (da Silva 2021).

In Mobitz II the PR stays constant before and after a P wave that suddenly fails to conduct, and the R-R spanning the block equals twice the other R-R intervals (Merck): an exact multiple, double for one dropped P and triple for two (LITFL). The block lies below the AV node. LITFL gives a broad QRS in about 75% of cases, where the block is in the bundle branches, and a narrow QRS in about 25%, where it is within the His bundle. Mobitz II fails suddenly and unpredictably, often in a patient who already has LBBB or bifascicular block, and LITFL gives the risk of asystole as about 35% a year.

In 2:1 block, conducted and blocked P waves alternate with a regular P-P and a constant PR on the conducted beats. Because two conducted beats never come in a row, there is no way to see whether the PR would have lengthened, so the strip is named '2:1 AV block' and not Mobitz I or II. Clues to the level (da Silva 2021): a normal PR and QRS point to the AV node or within the His bundle; a bundle branch block points below the His bundle. The Brazilian 2022 guideline adds that most 2:1 blocks are intra- or infra-His, and its exercise guideline notes that 2:1 block can be preceded by a run of Mobitz I or II and that 2:1 block brought on by a faster rate is usually His-Purkinje disease. A longer recording that shows a Wenckebach cycle or a Mobitz II drop in the same patient helps the reader. A blocked PAC on every second beat can imitate 2:1 block; the P-P will not be regular.

Terms differ by source. Merck calls any block of every second P wave or more 'high-grade'; da Silva and the Brazilian guidelines keep 2:1 separate and reserve 'advanced' or 'high-grade' for 3:1 or higher, where fewer than half of the sinus P waves conduct. The bank follows the second usage.

High-grade and third-degree block

High-grade (advanced) block conducts fewer than half of the sinus P waves, in a 3:1, 4:1 or higher ratio. Conduction is recognized by the same PR on every beat that does conduct, and most of these blocks are intra- or infra-His (Brazilian 2022). Junctional escape beats may fill the long pauses; an escape beat comes late, at the end of a pause, not early.

In third-degree (complete) block no P wave reaches the ventricles. A pacemaker below the block takes over, the P waves and QRS complexes are unrelated, and the atrial rate is faster than the escape rate. Measure the atrial and the ventricular rates separately. The escape tells the level: a junctional escape above the bifurcation of the His bundle is narrow at about 35 to 55/min; a ventricular escape is wide at about 20 to 40/min and less reliable (Merck, da Silva 2021). A supra-Hisian escape looks like the patient's usual QRS (Brazilian 2022), so a patient with a known bundle branch block has a wide junctional escape; compare with the old tracing before calling it ventricular.

Causes, as background for the report: idiopathic fibrosis of the conduction system (about 40%) and ischemic heart disease (about 20%) lead; drugs (beta-blockers, calcium channel blockers, digoxin, amiodarone), high vagal tone, sarcoidosis and Lyme carditis also cause block. Block in inferior MI is usually nodal and often resolves within days; block in anterior MI reflects necrosis of the His-Purkinje system (Merck).

AV dissociation that is not block

AV dissociation means only that the atria and ventricles are driven by separate pacemakers (LITFL). Complete heart block is one cause. Others need no block at all: the sinus rate falls below the rate of a lower pacemaker, or a junctional or ventricular pacemaker speeds up past the sinus rate, as in AIVR, junctional tachycardia or VT. The Brazilian 2022 guideline lists the mechanisms as replacement, interference, AV block and arrhythmia; it describes two dissociated rhythms, usually a regular sinus rhythm and a regular junctional or ventricular rhythm, and calls the form in which their rates are similar isorhythmic dissociation.

Right and left bundle branch block

When a bundle branch fails, that ventricle is activated late, muscle cell to muscle cell, so the QRS widens to 0.12 s or more and changes shape. Normal adult ventricular activation gives a QRS of 0.11 s or less (Merck). Abnormal depolarization brings abnormal repolarization: the ST segment and T wave point opposite the main or terminal QRS deflection. This 'appropriate discordance' is expected and is not ischemia.

FeatureRBBBLBBB
V1rsr′, rsR′ or rSR′; late R′Dominant S: rS or QS; small or absent r
I, aVL, V5–V6Wide, slurred S (in I and V6, S longer than R or over 0.04 s)Broad, notched or slurred R; no q wave; R-peak time over 60 ms in V5–V6
Expected ST-TST depression and T inversion in V1–V3ST and T opposite the QRS: depressed after tall R, elevated after deep S
MI on the ECGStill readableHidden; concordant ST change is the clue
Who has itUp to 1.6% of women and 4.1% of men, 14.3% of men over 80; can be normalUnder 1%, 5% at age 80; about 30% of patients with heart failure

Criteria above are Merck's and LITFL's; the Brazilian 2022 guideline accepts 120 ms as the minimum for LBBB but notes that classical LBBB is 130 ms or more in women and 140 ms or more in men, with an axis usually between −30° and +60°. Prevalence figures are da Silva 2021.

RBBB can appear without heart disease, but it is also caused by right ventricular strain (cor pulmonale, pulmonary embolism, where a transient RBBB signals significant right ventricular dysfunction), ischemic, rheumatic and congenital heart disease, myocarditis, cardiomyopathy and degenerative disease of the conduction system. Isolated RBBB without other conduction disease does not appear to raise future risk (Merck). The right bundle is usually supplied by perforating branches of the LAD, so a new RBBB with chest pain is highly concerning for an occluded artery (LITFL). Brugada syndrome can also draw an RSR′ in V1–V3. An rSR′ with a QRS under 0.12 s is incomplete RBBB (LITFL), which can be a normal variant; check that V1 and V2 were not placed too high, which can draw the same rSr′ pattern (Brazilian 2022).

LBBB is unusual without organic heart disease (LITFL): aortic stenosis, ischemic heart disease, hypertension, dilated cardiomyopathy, anterior MI, degenerative conduction disease, hyperkalemia and digoxin toxicity. Unlike RBBB, it carries a higher risk of future cardiac events and death (Merck), and it makes the two ventricles contract out of step, which can worsen heart failure. Transcatheter aortic valve replacement causes new LBBB in 14.0 to 45.2% of patients across studies (da Silva 2021).

LBBB hides an infarct. Its expected discordant ST elevation after the deep S waves of V1–V3 is generally under 25% of the depth of that S wave (LITFL). The findings a provider looks for (Sgarbossa, weighted 5, 3 and 2 points in the original score): ST elevation of 1 mm or more in the same direction as the QRS; ST depression of 1 mm or more in V1, V2 or V3; and discordant ST elevation of 5 mm or more (Brazilian 2022). The tech's job is to recognize concordant changes and get the tracing, with an old one, to the provider; the score is the provider's.

Bundle branch block can be intermittent or rate-related: a bundle that conducts at a slow rate fails at a faster one (acceleration-dependent block), more rarely the reverse, and an early beat in AF after a long cycle can be conducted with an RBBB shape (Ashman phenomenon; see the Rhythm Gallery). Da Silva 2021 lists acceleration- and deceleration-dependent block, the Ashman phenomenon, pre-excitation, drugs and electrolyte disturbances among the causes of intermittent conduction changes. A slow sinus rhythm with a bundle branch block is still sinus: check for a P wave before every wide QRS before accepting a monitor's 'ventricular' label.

Fascicular blocks, bifascicular and 'trifascicular' block

The left bundle divides into an anterior and a posterior fascicle. Block of one of them shifts the axis while the QRS stays under 0.12 s, because the other fascicle still reaches the left ventricle, about 20 ms late (LITFL).

CriterionLAFBLPFB
AxisLeft: −45° to −90° (LITFL); Merck: more negative than −45°Right: beyond +90° (LITFL); Merck: beyond +120°
I and aVLqRrS
II, III, aVFrSqR
R-peak timeOver 45 ms in aVLOver 45 ms in aVF
QRS80–110 ms80–110 ms
How common0.9–6.2% of people; not a risk factor when isolatedRare alone; usually seen with RBBB

LPFB is diagnosed only after other causes of right axis deviation are excluded: right ventricular hypertrophy, acute pulmonary embolism, tricyclic overdose and lateral STEMI (LITFL), and a slender build or old lateral infarct (Brazilian 2022). Left axis deviation has other causes too; LAFB needs an initial r wave in II, III and aVF, so QS complexes there with left axis point to something else, such as an old inferior infarct, and the differential diagnosis includes body build and pathologic Q waves (da Silva 2021).

Bifascicular block is RBBB with LAFB (left axis; up to 1.5% of adults) or with LPFB (right axis). Conduction then depends on the one remaining fascicle. Progression to complete block runs about 1–4% a year overall and about 1% a year without symptoms, but 17% a year in patients who present with syncope (LITFL), so a history of fainting goes in the report. LBBB itself is sometimes counted as bifascicular, because both left fascicles are involved (da Silva 2021).

True trifascicular block is bifascicular block with third-degree block. Bifascicular block with first-degree block is still often called 'trifascicular' (once 'incomplete trifascicular'), but LITFL, Merck and da Silva all call this inaccurate: the long PR usually comes from the AV node, not the third fascicle, and LITFL reports that the AHA/ACCF/HRS recommends against the term. First-degree block does not change the roughly 1% yearly progression in asymptomatic bifascicular block (LITFL). Alternating bundle branch block, RBBB on some beats and LBBB on others, or RBBB with alternating LAFB and LPFB, is trifascicular disease (Merck) and is reported at once.

Nonspecific intraventricular conduction delay

A wide QRS (Merck: over 0.12 s) that fits neither the RBBB nor the LBBB pattern is a nonspecific intraventricular conduction delay (IVCD). It can come from slow conduction through the muscle beyond the Purkinje fibers, as in severe hypertrophy and cardiomyopathy (Brazilian 2022 calls this parietal or focal block). Its risk of later cardiac events and death is similar to LBBB, so it prompts a search for structural heart disease (Merck). Before calling a wide QRS an IVCD, consider what else widens it: pre-excitation (look for the short PR and delta wave), ventricular pacing (look for spikes), hyperkalemia and sodium-channel-blocking drugs.

Drug, electrolyte or stateWhat it does to conduction on the tracing
Beta-blockers, verapamil, diltiazem, digoxin, amiodaroneLonger PR; Mobitz I; can reach complete block
High vagal tone (athletes, sleep)First-degree block and Mobitz I; more pre-excitation in WPW
HyperkalemiaAV block, including Mobitz II; wide QRS and bundle branch patterns
Digoxin toxicityAV block; LBBB pattern among its causes
Tricyclic overdoseRight axis deviation that can mimic LPFB
AdenosineBrief AV nodal block; unmasks a pathway as more pre-excitation

Sources for the table: LITFL Mobitz I, Mobitz II, third-degree, LBBB, LPFB and pre-excitation pages; Merck 'Atrioventricular Block'; Elendu 2025 for adenosine.

Pre-excitation and WPW

In pre-excitation an accessory pathway, a strand of muscle across the AV ring, carries the atrial impulse to part of the ventricles before the AV node does. That early activation is the delta wave, and it shortens the PR. The rest of the QRS is drawn by normal conduction through the AV node, which arrives and takes over (LITFL). Each QRS is therefore a fusion of two routes, and anything that slows the AV node, such as vagal tone during a Valsalva maneuver or AV-nodal blocking drugs, shifts more of the ventricle onto the pathway and makes the delta wave bigger (LITFL). By the same logic a premature atrial impulse, slowed in a partly recovered AV node, gives a wider pre-excited beat.

The tachycardias: in orthodromic AVRT, about 95% of AV reentrant tachycardias, the circuit runs down the AV node and back up the pathway, so the QRS is narrow (unless there is a bundle branch block), the rate is 120 to 250/min and regular, the delta wave disappears, and a negative P wave sits in the first half of the R-R in II, III and aVF (Merck). A concealed pathway, which conducts only backward, gives a normal resting ECG but the same orthodromic tachycardia. In antidromic AVRT the circuit runs down the pathway, so every beat is fully pre-excited and the tachycardia is regular and wide; LITFL notes it may be impossible to tell from VT without the history or an old tracing showing a delta wave.

Pre-excited AF: why it is urgent and what to measure

AF develops in up to 50% of patients with WPW syndrome (Schiavone 2024). The AV node normally limits how many fibrillatory impulses reach the ventricles; a pathway with a short refractory period does not, so the ventricular rate can reach 200 to 300/min, with R-R intervals as short as 160 ms, and the rhythm can degenerate to VF and sudden death (Merck). The tracing is fast, irregularly irregular and mostly wide, and because each beat is a different mix of pathway and AV node conduction, the QRS width and shape change from beat to beat, with an occasional narrower complex that does not follow a long pause (Merck). AF with a fixed bundle branch block, the main look-alike, keeps one QRS shape.

The shortest pre-excited R-R interval (SPERRI) estimates how fast the pathway can conduct: 250 ms or less marks a pathway linked to VF (Schiavone 2024, Merck). At 25 mm/s that is 6¼ small boxes; measure the shortest interval between two consecutive wide beats on the whole recording, not a typical one. Other markers named by Merck are younger age, exercise, earlier tachycardias and multiple pathways. Manifest WPW carries an estimated 1.5% yearly risk of AF and about 0.1% yearly risk of sudden death, and sudden death can be the first sign, especially in adolescents (Merck).

Why the drug history matters to the tracing: digoxin, adenosine, verapamil and diltiazem slow the AV node but not the pathway, may increase the ventricular rate in pre-excited AF and cause VF, and are contraindicated (Merck); Schiavone 2024 adds that amiodarone may enhance pathway conduction. A tech who sees an irregular, very fast, wide rhythm with changing QRS shapes, or who knows from an old tracing that the patient has a delta wave, says so when reporting, because that changes the provider's drug choice.

  1. Look at the patient: responsive, breathing, pulse?
  2. Alert the nurse or provider at once and say 'irregular wide-complex tachycardia, possible pre-excited AF'; mention a known WPW pattern or delta wave on an old ECG.
  3. Print and keep the strip; on a Holter or event recording, mark the episode and its shortest R-R.
  4. Stay with the patient. If the patient becomes unresponsive and pulseless, call the code team, start CPR and use the AED if trained.

Conduction findings in the stress lab

These points come from the Brazilian 2024 adult exercise test guideline; follow your own lab's contraindications and stop criteria, which the supervising provider applies.

FindingWhat the guideline says
First-degree block at restUsually shortens with exercise
Mobitz I at rest, healthy, no symptomsNot a contraindication; conduction usually normalizes
Mobitz I during exerciseStop criterion with symptoms, more blocked beats, or a rate that falls as work rises
Mobitz II on the resting ECGContraindication to the test
Acquired complete block at restContraindication to the test
Mobitz II or complete block brought on by exerciseStop the test
2:1 brought on by a faster rateUsually His-Purkinje disease
LBBB or WPW at restST changes cannot be read for ischemia
RBBB at restST changes unreadable in V1–V3 only
LBBB appearing during exerciseIn about 0.4–0.5% of tests; onset at 125/min or less strongly linked to coronary disease

After an exercise-induced LBBB resolves, deep symmetric T-wave inversions in V1–V4 on normally conducted beats are an effect of the block itself and are not read as ischemia (Brazilian 2024). Note the heart rate at which any block appears and disappears; it is part of the report.

Documenting and reporting

FindingDocumentReport
First-degree blockPR in secondsRoutine; sooner if new or the patient has symptoms
Mobitz ICycle ratio (e.g. 4:3), PR range, QRS widthPer protocol; at once with symptoms
Mobitz II, 2:1, high-grade, third-degreeAtrial and ventricular rates, PR on conducted beats, QRS width, longest pauseAt once; check the patient
New bundle branch blockQRS width, V1 shape, old tracing for comparisonAt once if chest pain or symptoms; otherwise per protocol
Alternating bundle branch blockStrips showing each patternAt once
WPW patternPR, QRS, delta wave polarity in V1Per protocol; note it on any later tachycardia report
Pre-excited AFRate, shortest R-R, time of onsetAt once; stay with the patient

The facility protocol sets the actual timing of each report. Describe what you measured rather than a label you are unsure of: '2:1 AV block, narrow QRS, PR 0.28 s on conducted beats' tells the reader more than a guess at Mobitz I or II.

Exam pearls

Practice free in your browser650+ exam-style questions with rationales. Free today, no account, no ads. Pro is coming in January 2027. Also free on Google Play.

Related cheat sheets

Sources

  1. Mitchell LB. Atrioventricular Block (AV Block). Merck Manual Professional Edition. Reviewed September 2024. Link
  2. Mitchell LB. Bundle Branch Block and Fascicular Block. Merck Manual Professional Edition. Reviewed September 2024. Link
  3. Mitchell LB. Wolff-Parkinson-White Syndrome (WPW Syndrome). Merck Manual Professional Edition. Reviewed September 2024. Link
  4. Mitchell LB. Atrial Fibrillation and Wolff-Parkinson-White Syndrome (WPW Syndrome). Merck Manual Professional Edition. Reviewed September 2024, updated October 2024. Link
  5. Right Bundle Branch Block (RBBB). Life in the Fast Lane ECG Library. Link
  6. Left Bundle Branch Block (LBBB). Life in the Fast Lane ECG Library. Link
  7. Left Anterior Fascicular Block (LAFB). Life in the Fast Lane ECG Library. Link
  8. Left Posterior Fascicular Block (LPFB). Life in the Fast Lane ECG Library. Link
  9. Bifascicular Block. Life in the Fast Lane ECG Library. Link
  10. Trifascicular Block. Life in the Fast Lane ECG Library. Link
  11. AV block: 2nd degree, Mobitz I (Wenckebach phenomenon). Life in the Fast Lane ECG Library. Link
  12. AV block: 2nd degree, Mobitz II (Hay block). Life in the Fast Lane ECG Library. Link
  13. AV block: 3rd degree (complete heart block). Life in the Fast Lane ECG Library. Link
  14. Pre-excitation Syndromes. Life in the Fast Lane ECG Library. Link
  15. Cadogan M, Buttner R. Delta Wave. Life in the Fast Lane ECG Library. August 2020. Link
  16. VT versus SVT. Life in the Fast Lane ECG Library. Link
  17. Sinoatrial Exit Block (SA block). Life in the Fast Lane ECG Library. Link
  18. da Silva RMFL, de Souza Maciel A. Conduction Disorders: The Value of Surface ECG. Curr Cardiol Rev. 2021;17(2):173–181. doi:10.2174/1573403X16666200511090151 Link
  19. Samesima N, God EG, Kruse JCL, Leal MG, et al. Brazilian Society of Cardiology Guidelines on the Analysis and Issuance of Electrocardiographic Reports – 2022. Arq Bras Cardiol. 2022;119(4):638–680. doi:10.36660/abc.20220623 Link
  20. de Carvalho T, de Freitas OGA, Chalela WA, Hossri CAC, et al. Brazilian Guideline for Exercise Test in the Adult Population – 2024. Arq Bras Cardiol. 2024;121(3):e20240110. doi:10.36660/abc.20240110 Link
  21. Schiavone M, Filtz A, Gasperetti A, Zhang X, et al. Pre-Excited Atrial Fibrillation in Wolff-Parkinson-White (WPW) Syndrome: A Case Report and a Review of the Literature. Rev Cardiovasc Med. 2024;25(4):125. doi:10.31083/j.rcm2504125 Link
  22. Elendu C, Babarinde FO, Babatunde OD, Babawale EA, et al. Risk stratification and management of arrhythmias in patients with Wolff–Parkinson–White syndrome. Ann Med Surg (Lond). 2025;87(5):2702–2717. doi:10.1097/MS9.0000000000003068 Link
  23. Ying S, Zhang J, Fu NK, Zhang P. Ivabradine in the treatment of non-paroxysmal junctional tachycardia with interference atrioventricular dissociation: A case report. Ann Noninvasive Electrocardiol. 2023;28:e13064. doi:10.1111/anec.13064 Link